Model Numbers
DS 230 | 1 relay, 4 control outputs push-pull, analogue output, signal splitter |
DS 236 | 1 relay, 4 control outputs push-pull, analogue output |
BG 230 | Display and programming module (optional) |
Features
- Suitable for the connection of incremental encoders or sensors with RS422 output (differential signals A, /A, B, /B)
- Free combinable with Sine-Cosine sensors or SinCos encoders with 1 Vpp
- Redundancy can also be achieved by HTL encoders or proximity switches
Specifications
Power Supply | 17VDC - 30VDC |
Ripple | ≥ 10% @ 24VDC |
Current consumption | approx. 70mA @ 24 VDC |
Aux. Output for encoder supply | 5.2V max. 200mA |
Inputs Control 1/2 |
Ri = 3.9 kOhms, Low < 2.5V, HIGH > 10V (max. 30V) minumum duration of dynamic signals: 50 µsec. minumum duration of static singals: 2 msec. |
Encoder inputs |
Symmetric differential sin/cos - input (sin+, sin-, cos+, cos), Signal level 0.8 Vpp - 1.2 Vpp, Singal offset approx. 2 - 3V to GND |
Input Frequency |
500kHz |
Analogue Output |
±10V, max. 2mA 0 - 20mA, 4 - 20 mA (load: max 270 Ohm) Resolution 14 bits, accuracy 0.1% Settling time approx. 200us Step response = 2 x sampling time + 200us |
Relays (DZ260 and DZ267 only) | Dry change-over contracts, switching capability 30V / 2A DC or 125V / 0.6A AC or 230V / 0.3A AC Response time approx. 4msec. |
Transistor Outputs (DZ 261 and DZ269 only) | 3 fast, short-circuit-proof PNP-outputs 5-30V, 350 mA, response time < 1 msec. |
Serial interface | RS232 / 2400 - 38400 Bauds |
Ambient Temperature |
Operation: 0 - 45°C ( 32 - 113°F) Storage: -25 - +70°C ( -13 - 158°F) |
Housing | Plastic housing, suitable for mounting to standard DIN rails (35mm) |
Display | LCD with backlight, 2 lines at 16 characters, 3.5mm size |
protection Class | IP20 |
Connections | 25 position screw terminals for cross sections of max. 1.5 mm² (0.0023 in²) |
Conformity and Standards |
EN61326-1:2006 EN61000-6-2:2006-03 EN61000-6-3:2007-09 |