Model Numbers
DX 342 | Electronic Counter (2 relays, serial RS232/485 interface) |
DX 345 | Electronic Counter (Display Only) |
DX 346 | Electronic Counter (Analogue output) |
DX 347 | Electronic Counter (2 presets / transistor outputs) |
DX 348 | Electronic Counter (serial RS232 / RS485 interface) |
Features
- Universal multi-function counters with multiple operation modes as qudrature counter, event counter, display or RPM, speed, cycle rate, baking and prcessing time and timer/ stopwatch functions.
- Counting Frequency 100 kHz (A/B qudrature count)
- Dimensions 96 x 48 mm (3.780 x 1.890") and 6 decade LED display at 15 mm (0.590" size
- Universal inputs for sensors and encoders with PNP/NPN or Namur characteristics (HTL level 10-30V)
- Easy scaling and setup by means of 3 front keys and menu support
- Selectable linearization function with 16 interpolation points
- Power supply 115/230 VAC or 24 VDC (model DX342: 24 VDC only)
Specifications
Power Supply Voltage | 24VDC (17-30V) |
Consumption (without sensor) | 18 V = 120 mA, 24 V = 95 mA, 30 V = 80 mA (approx.) |
Aux. Voltage for encoder supply | 24V DC, ±15%, 120 mA (5 VDC / 120 mA with option TTLIN1) |
Inputs | 3 (PNP/NPN/Namur), A/B = Impulse, C = Reset |
INput Currents | 5.1 mA / 24 V (Ri = 4.7 k Ohms) |
Input Level HTL (Standard) | Low: 0 - 3,5 V, High : 9 - 30V |
Input Level TTL (option TTLIN1) | CMOS levels, Low: 0 - 0.8V, High: 3.6 -5.0 V |
Max. input Frequency |
All Counter Modes: 100kHz All other operating modules: 25kHz Reset input C: 1 kHz (min. Pulse duraction 500 usec) |
Dispaly update Rate | Approx. 7 msec (330 msec with tachometer operation) |
Accuracy (frequency measurement) | ±1 ppm ±1 Digit |
Serial Interface | RS232 or RS485 ( Switch selectable) 600 - 38400 bauds |
Ambient Temperature |
Operation: 0° - 45°C (32 - 113°F) Storage -25° - +70°C (-13 - 158°F) |
Housing | Norly UL94 - V-0 |
Display | 6 Digit, LED, high-efficiency orange, 15mm (0.59") |
Protection Class | Front IP65, Rear IP20 |
Terminals | Singals max. 1.5mm², relay outputs max. 2.5 mm² |
Relays | 2 x dry change-over contacts, each 250 VAC / 1A / 250 VA or 100VDC / 1A / 100 W |
Weight (net) approx. | 450g |
Conformity and Standards | EMC 2004/108/EC: EN61000-6-2, EN61000-6-3; LV2006/95/EC: EN61010-1 |